Carbon dioxide extinguishes fire by diluting the oxygen content of the space to a point where it will not support combustion. Reducing the oxygen will extinguish most fires. “Surface” or “Flash” type fires (Oils, paints, etc,) are quickly extinguished, “Smoldering” or “Deep-Seated” fires (baled cotton, clothing, etc.) are extinguished by prolonged action of a high concentration. Retaining the agent within the protected space affects the ability to avoid resignation. In addition, carbon dioxide has a cooling effect on the surrounding atmosphere, which has been found to be a benefit to extinguishing. |
| Some of the more important types of hazards and equipment, that carbon dioxide may satisfactorily protect include : Data Center, Telecommunication Equipment, Tape Storage facilities, Flammable Liquid Storage, Chemical Processing Equipment, Electrical Equipment, Dip Tanks / Quench Operations, Test Cells, Food Processing Equipment, Spray Booth, Printing Process, Power Generation, Coating Machine, and etc. | ![]() |
|
|
![]() |
The
extinguishing clean agent used for our Total Flooding Systems more commonly
known as FM-200 TM (HFC-227
ea) or in chemical named Heptafluoropropane (CF3CHFCF3).
FM-200TM Ozone Depleting Potential (ODP) is “Zero” and is considered nontoxic to humans concentrations necessary to extinguish most fires. FM-200TM is invented to substitute Halon 1301 as Halon 1301’s ODP value is still 16, however; their fire extinguishing efficiency is nearly equivalent. |
|
|
|
![]() |
Sprinkler
System is composed of sprinkler heads, sprinkler alarm, piping, automatic
pump & valves, controlling devices and water supply.
Sprinkler systems are classified into Wet-pipe and Dry-pipe system. |
| Sprinkler is one choice of economy since water is lower cost than gas and some cases, the user could take from the natural resources, therefore; Sprinkler system is suitable for installing in large area such as car parks, hotel rooms, factories which would not be damaged by water and electricity areas. |
|
|
![]() |
Hydrant is one choice for the manual system which designing based on easily using and inexpensive expense; however, the user should have well knowledge and experience. The main components for Hydrant is consisted of hose cabinet, hose reel/hose rack with nozzle tube, automatic pump, piping and flow control valve. |
|
|
![]() |
The
most efficiency extinguishing agent are commonly known as Halon 1301 or
in chemical named Bromotrifluoromethane which is also considered nontoxic
to humans concentrations necessary to extinguish most fires.
Affer discharge, Halon 1301 requires no cleanup making it extremely useful in applications where damage by other extinguishing methods would be prohibitive such as important documentary storage, electronic equipment-computer room and the closed hazard. Though Halon 1301 is not further produced in present but there are some special areas e.g. airplane that still need Halon 1301 since present the 100% Halon substitution could not be found. |
|
|
![]() |
The economy choice for fire extinguishing compares with gaseous type. When discharge, foam expands quickly on the surface of the burning area during the rate of 2:1 to 1000:1. |
| Following are some areas satisfactory protected: Grease or oil areas e.g. petrol tank, and deep-seated fuel e.g. Plastic & Sponge warehouse and etc. | ![]() |
|
|
![]() |
Water Spray system’s components are similar to Sprinkler system except the higher water pressure because of the farther distance water spray and higher water flow rate than Sprinkler. |
| The suitable area for installing Water Spray system such as Electricity Generator , Factory, Oil Refinery, Car tunnel and etc. | ![]() |
|
|
![]() |
Fire
Alarm Systems are classified into manual and automatic system :
- Manual Fire Alarm System is composed of control panel, manual release station and alarm devices. - Automatic Fire Alarm System components are as same as in Manual System with Automatic Detectors and including Telecommunication system for the large area. |
![]() |
Kitchen
is one of the high risky fire areas due to spark occurring in normally,
Therefore, should have the special fire extinguishing system especially
for kitchen area. The nozzle area should coverage the source of the fire
and the possible spread area.
The suitable extinguishing agent for oil and grease fuel is Formulate Potassium Acetate. |